Meter pole specifications Below are some residential and commercial diagrams and specifications for your planning needs. 200 amp meter loop can be purchased through MEC for $680-780* plus applicable taxes. Current Transformer Enclosures - Manufacturers & Specs; Meter Sockets - Manufacturers & Specs; Meter Main/combinations - Manufacturers & Specs; Meter Pedestals - Manufacturers & Specs TUBULAR POLES I - (7. It is intended to provide guidance only regarding the design and installation of electric 5. Baxley covered requirements Figure 21A. locknut and fiber-bushing inside meter socket on metal nipple. of Single Phase meters or meter loop installation guide for: METER POLE 200 AMP SERVICE, 120/240 VAC Bill of Material: 1 1 16’ (min. Tri City. Load break disconnect (see note 4). 04 Application for Service It is important that the local Utility office be provided as early as possible with accurate load information and the date when the customer will require service, so all necessary 1. See note below. Precautions must be taken when trenching near poles to Moss Bluff Office. Find Closest. Fully pressure treated. ( my county the utility limits the meter to 6') so your panel Below are many often-referenced construction forms and policies. Meter Pedestal Specs. 1 mm) SCH40 POLE BASE Overhead Temporary Meter Pole; Underground Service. 13'-6" min. SERVICE DISCONNECTS shall be manually operable and shall have over current protection (either fuses or circuit breakers) rated not to exceed the ampacity of the service entrance 40 or greater, electrical grade PVC, and the service riser to the meter socket shall include an expansion coupling that allows for 8” fall. Meter Pole Installation - Underground Service - Single Phase. must be at least . General 35 801. Figure 21A. Navarro County Electric Cooperative, Inc. s. 3. bracing mounted at 2/3 height of Find meter pole specs; Find NCEC forms Update my contact info; Contact Us; Contact Info. It also covers solar meter installations, Specifications for Residential Overhead Meter Pole Requirements Applicable to residential and small noncommercial services receiving single-phase power at 120/240 volts VIII. Service entrance conductor’s and service raceway provided and installed by customer. 3 – Single-Phase Underground Service Requirements from a new Padmount Transformer Drawing No. to 5 p. There Cleco's electric service standards are meant to aid customers, architects, builders, contractors, developers, engineers and others in planning electrical installations that will connect to Cleco's electrical system. See 9. It lists the pole height as 9000mm with a top diameter of 100mm and bottom diameter of 200mm, along meter pole - meter loop specifications 6-2016 weatherhead metal threaded conduit 1. Meter Mounted on Pole - 320 Amp SPEC is closed for all major holidays. 4, co/UI1'" heading D ) - Bracketed wording '( Outside Dra of Bottom Plate )' may be read under 'A'. Learn about the general requirements and specifications for meter pole installation for residential and non-residential services by DREMC. Height above Ground. Self-Contained Meter Socket Connections (Three Wire and Four Wire Delta) 15 SLEMCO . 0 3-Phase Meter Installation, Common Distribution Point 108 3-Phase, Meter Installation Distribution Point 109 17. ), 6” X 6” treated pole 2 As Req’d 2/0 stranded copper cable with 90 C Insulation rating Type RHH, THHN, THHW, or XHHW. Residential/small non-residential 120 volt (two wire) Overhead self contained; Underground self contained; 277/480 volt service on pole (overhead) 277/480 volt service (from Neutral wire may be bare. If you can't find the pole size, contact the Austin Energy team you are working with on your development project. The meter pole shall be installed a minimum of 36” below finished grade. Sustainability. 1-4 — Meter Pole (Single-phase Overhead Load Connection) Installation Specifications. C&L Furnishes. txt) or view presentation slides online. 4) Customer is responsible for all conduit, neutrals, grounds, and bonding. Location and contact information. 5" #2 #4 #6 * 2" 2/0 3" 4/0 #4 COPPER Current This amount is a non-refundable contribution to Aid of Construction. Price. MCS0077. Beginning January 2, 2019, only the 20 18 edition of the Customer Installation Standards will be accepted. meter, watthour, 1 phase, 3 wire, self contained tamper proof 3) pole specifications: 4”x4”x16’ treated post or 6”x16’ round treated post at minimum. Toggle navigation. 7 %âãÏÓ 511 0 obj > endobj 535 0 obj >/Filter/FlateDecode/ID[]/Index[511 186 705 1]/Info 510 0 R/Length 129/Prev 2664462/Root 512 0 R/Size 706/Type/XRef/W All service entrance equipment shall be supplied and installed on the meter pole or st ructure by the Consumer. Starting at $1200 Delivered and installed on your property. Our poles range from 2. Self-Contained Meter Socket Connections (Three Wire and Four Wire Delta) VIII. TECHNICAL SPECIFICATIONS OF PCC POLES (F. Customer shall permanently mark each meter socket at multi-meter locations before a meter can be set. 3 – Single-Phase Underground Service Requirements from a new Padmount Transformer If your project requires new construction by Oncor, for example, new poles, wire, or transformers, Subtract Meter Base Specs - Stock No 301391. Fence Clearances - Padmount Transformer. Pole Mounted Meters 37 805. _F023. unspliced or 5" minimum diameter creosote pole. Typical Overhead CT Cabinet & Meter Equipment Clearances Wall Mount Above Flood Figure 22. Meter Position 36 804. Wiring diagrams are available below. Subtract Meter Guidelines. Includes two 5/8-in x 8-ft copper plated ground rods. Underground Service Specifications The specifications for underground service and meter base. Correct meter base . Temporary meter loop for underground service Single or three phase 60-200 amp temporary meter loop for transformer and service poles 15 feet meter loop, single phase or three phase, 60-200 amp meter loop on meter pole 19 feet meter loop, single phase or three phase, 60-200 amp meter loop on meter pole 1. -2. 600 volt multi-conductor cable. This document provides detailed technical specifications for a 12 meter high mast pole, including: 1. single-phase overhead type distribution transformers 500 kva and smaller. Ø142mm x 4000 mm HEIGHT. Designation of Tubular Poles. 1618 This document is the property of FortisBC and is for authorized use only. see note: 2 5) two braces required in the direction of the service wire from transformer. drawing - pole drilling specs. s. 1 )--Substit ute the letter symb0 I 'P', for 'p' and read as under: "P - Wind pressure on flat surfaces in N/m2, to be calculated in accordance with the provisions of IS: 875-1964 'Code of practice for structural safety of 6 Meters Light Pole Component Specifications STEEL POLE 1,Material: Steel Q235 2,Hot dip galvanized thickness not less than 80um 3,Height:6m 4,Top Diameter: 120mm 5,Bottom Diameter: 200mm 6,Thickness:3. conductor tails 1. 12'-0" min. Office Hours. Home Gate Barrier Gate Barrier Gate Accessories 2 METER METAL POLE. MEC provides the meter can to you. From application requirements to fielding questions about meter loop specifications—quite frankly, there’s a lot to know. 1-2 — Overhead Meter on Home or Building (Service Mast Attachment) Installation Specifications. toll free: 800-338-6425 | 888-850-6551 | for automated payment system please call 833-536-0427 CUSTOMER INSTALLATIONSTANDARDS FOR ELECTRIC SERVICE September 4, 2018 A transition period will exist in which installations may be approved and connected as long as they meet either the 20 13 or the 2018 editions. net. B. Highway 21 East P. Technical Technical specifications of Multi-meter box made out of glass reinforced polyester sheet moulding compound (S3 grade)/ Polycarbonate/ CRCA MS Deep Drawn or Fabrication for housing 4/8/12/18 nos. The latest meter pole training workshop was taught by Sam Houston EC Staking Supervisor Cloy Baxley. 5- General specifications: The street lighting poles shall be manufactured from steel sheets and having the following features. Meter Loops & Power Poles $ 884. Temporary meter pole must be strapped to pole rise r conduits-> (sect. Format application/pdf. Meter Socket provided by MSS and must be installed by Member. Hawaii Island Requirements & Specifications. Electric Meter Requirements. 2’ max. 0 M) - LIGHTING & POWER TRANSMISSION. Access to meter location. 16 SLEMCO Specifications for Residential Underground Meter Pole Requirements Items marked with wert are indicated on the following drawings: wDrawing No. Load Applied from Top at a Distance of. A TALLER POLE . Non-Residential Meter Pole Specs. e. 4 – Typical Overhead CT Cabinet & Meter Equipment Clearances Wall Mount Above Flood Level Figure 22. During business hours call us here, 903-846-2311 or to report an outage get your meter number and call the 24 hour outage hotline, 1-877-707-2232 18' PINE POLE, CREOSOTED OR PENTA POINT OF ATIACHMENT . Exceptions! (1) The minimum setting depth may be reduced to three feet with 2×4 min. Permanent: meter pole must be a treated 20 feet in length round pole and set 5 feet deep, with a minimum top diameter of 6 inches. 05. 8 meters in height and 114mm to 165mm in diameter. Charges member owned meter pole, temp poles, or meter bases. All fees that are due to FLEC must be paid prior to hook up. 2. Follow their guidelines on mounting procedures and drawing - pole drilling specs. • the meter pole shall meet all of the electric service installation manual,n. It consists of the weatherhead, the service mast or riser, and the meter enclosure. 25 Ft. three straps are required. 4) leave min 18” of wire extended out of weatherhead for driploop. * meco will install the service drop & meter, and will provide the attachment to be to be installed by the customer. S. They have a 16 circuit breaker box and 8ft copper ground rod when installed. metering area. 9. three. EES Spec Sheet; MFR Spec Sheet Quick Specs Catalog Number ENTE200A18FTP Vendor Code MPW Manufacturer Meter Loops & Power Poles Manufacturer's Part Number N/A Description Entergy 200A 18' Pole be added to pole but must have 120v g. Madisonville. Account Login Apply for Service Capital Credits Collection/Non-Pay METER LOOP SPECIFICATIONS FOR SINGLE PHASE SERVICE www. Meter Socket provided by MSEC and must be installed by Member. 250-83) apart per n. Meter Socket Layout for Adding a Separately Metered Electric Vehicle Service Figure M. minimum conductor sizing rv- pole service march 2019 a. These poles are manufactured in steel CHS pipe and hot-dipped galvanised. Almost all residential and small commercial buildings have a meter base installed on an exterior wall, with the service point at the meter base. 25 Foot Meter Poles and Fused Disconnect Poles *Effective August 1, 2022. Fayette Electric is to be notified when loop is ready for inspection. 1 Purpose The information contained in this document is presented for use by First Electric Cooperative members, Conroe Meter Poles provides installation and residential connection services available - free quote provided upon delivery of pole in Houston & Southeast Texas. Typical Application. 2 – Single-Phase Underground Service Requirements from an Existing Padmount Transformer Drawing No. Wiring specifications can be found at further down the page, or by request. CALL FOR PRICE with NYSEG's specifications (see Figure 20) and the National Electrical Code. top of page. QTY Description 1 20 Pole Attachments - Forms and Specifications Drawing 1 - Communication Cable Clearances and Requirements Tangent Construction Drawing 2 - Communication Cable Clearances and Requirements Midspan Figure 21A. POLE - Free download as PDF File (. 62 (Each) $884. You will need to provide: Primary and joint account holder's (if any) full Social Security number(s). The document provides specifications for a 9 meter high galvanized octagonal pole, including the height, diameters, thickness, base plate details, and foundation details. the meter socket, panels, conduit, underground cable, poles, racks, weatherhead, etc. Meets spec for: Pedernales Electric Coop Sale Price! Add to Favorites Add to Quotes Supplier SKU: Web SKU: ML100000208 Meter Loops and Power Poles PEC 200A-20 Description Specifications 200 Amp, Combination Meter Socket & Panel with 20 ft treated pole TUBULAR POLES I - (10. 3 ft. samhouston. Any other energy providers can be custom built to the needed specs. min. Test Switches: 4 through 10 pole configurations available, built to customers specifications for layout, connector marked on meter enclosure, pole, or durable material attached to pole and should be visible from street. Construction Forms. DREMC representative must inspect the open pole hole and hole shall not be more than two times the diameter of the pole. Temporary Meter Pole Specs. See drawing D2-1. Service to permanent pole location (serves mobile homes and some buildings) Overhead; Underground; Mobile home park (5 or more contingent lots, same owner) Meters. Report an outage. 200 Amp Meter Pole Specs. PO Box 1058 Marshall, TX 75671-1058. 100. Overall Length. 6" Nipple (see note 7). 5 M) - LIGHTING & POWER TRANSMISSION. Box 736 San Augustine, TX 75972 936-229-4000 NAME DATE TITLE DWG NO. DATE: 0 1/ 08 /2 5 APPROVAL: C. A 30-foot lift pole is required if the Member’s MOP (meter pole) is less than the standard 23 foot MOP . To ensure the safety of our customers, employees, your employees, and the contractors we each employ, it is imperative that every third-party attachment to Entergy facilities comply with National Electric Safety Code standards as well as Entergy construction Meter Pole/Trailer Pole Specifications The specifications for a trailer pole. . 3800 W. 0 Residential Specifications 30 OH Service Clearances 30 Residential Underground Service Installation 31 4-Wire, 3-Phase, OH to UD, Customer Pole 77 4-Wire, 3-Phase, CT Transocket, on Pedestal 78 4-Wire, 3-Phase, Transocket, (400A This guide provides specifications for metering configurations for most services under 750 volts. Grounding - 3-Wire Residential. Economic & Business Development. Stop service request. DREMC representative must field check site and indicate location for pole and anchor by placing stakes. (2 each) ? " x 8' g eneral no te s : * consult with meco for location of pole. Self-Contained Meter Socket Connections (Single Phase and Network) • the meter pole shall be strong enough to support all service wires with maximum wind loading. V. Highway 22 P. , LTD MEMBER METER POLE . QTY: Each. All customer meter poles and temp poles must pass a state electrical inspection prior to hook up. Circuit breaker or fuse box (see note 4 Pole attachments - forms and specifications Drawing 1 - Communication Cable Clearances and Requirements Tangent Construction Drawing 2 - Communication Cable Clearances and Requirements Midspan Spec. d) The mix should contain as low a water content as is consistent with adequate work ability, if it becomes necessary to add water to increase Pole sizes may be shown on the pole tag, but may be worn off due to weathering. 2. Superb pole . Meter poles are furnished and installed by member. Article 416. %PDF-1. Single-Phase Switch Can or Padmount Transformer Foundation – Drawing No. Conduit extended to height of 6’5” above top of meter base - On 100-AMP service: 1 ¼” EMT conduit - On 200-AMP service: 2” EMT conduit - On 320-AMP service: 3” EMT conduit 200amp meter main load center mounted on 25' pole. o Note 6: Added Never install member -owned poles and/or PEC poles under overhead electric lines. 3 1 2” Weatherhead 4 4 2” conduit straps with screws (Nails NOT acceptable). point of attachnent (see notes 8 & 10) maxihum recommended distance amps length up tp sop 60 350 i£ rigid galvanize or sch 80 pvc (no emt pipe) meter loop installation guide for: METER POLE 100 AMP SERVICE, 120/240 VAC Bill of Material: 1 1 6’ (min. pdf. 4 – A single enclosure that allows for multiple meters. The photo is a representative image and the actual product may be different. neutral conductor should be identified. For local customers in need of meter poles manufactured to Puget Sound Energy specifications, call The Oeser Company, we’ve got you covered! Puget Sound Energy (PSE) Meter Pole Specifications. 00. It lists the pole height as 9000mm with a top diameter of 100mm and bottom diameter of 200mm, along with other technical specifications for the pole, base plate, and foundation. Clearance for Metering Equipment 39 809. Find out the clearance, conduit, and grounding Members are responsible for supplying and installing entire assembled meter loop. Size 104 KB. 25 Foot Pole (No Disconnect or Meter Base) Overhead service (bare pole only) $820. As of December,2019 it meets all the requirements of CPS Energy in San Antonio but customer must verify it still meets the utility company specifications as they often change. c. Typical Overhead CT Cabinet & Meter Equipment Clearances Wall Mount Above Flood Level Figure 22. Your "Meter" - a device for measuring the electric power and energy supplied to a customer. 26 Meter Socket A receptacle of weatherproof construction used for mounting a socket type meter. 1 latest edition and is to be full length<br /> pentachlorophenol, CCA, or creosote treated in accordance with MEC will set meter poles and that cost will be included in the estimate. Added: “Meter Rooms shall be identified with a permanent sign, “Electric Meter Room”. 14'-0" min. Electric Meter Locations; Self-Contained Electric Meter Meter sockets must conform to specifications furnished by Tri-County Electric Co-op 4. 6; Overhead Meter Pole Guying – Drawing No. Class 6 or better with a minimum diameter of 5-1/2 inches at the top. Items marked with are indicated on the following drawings: Drawing No. Service point for an underground system with secondary meter socket installed on side of building. Rigid/Intermediate metal (steel), rigidaluminum, EMT or schedule 80 PVC greyconduit, with U. 1 refer to note 5 below refer to note 3 below customer must prov de 24 nches of wire ends at head Steel meter poles: These offer increased durability and strength compared to wooden poles. Temporary Underground Meter Pole Specs. 1-5 — Meter Pole (Three-phase Underground Load Connection 30 Foot Lift-Pole – A WCEC pole installed to support a Member’s service drop so that proper above ground clearance can be maintained. Specifications shown on the drawing and described here shall be considered minimum requirements. See table for distance 5'-0" to 6'-0" Maximum Recommended Distance Length 320 40' Amps 100 200 100' 75' 911 address shall be a minimum 3" lettering marked on meter enclosure, pole, or durable material attached to pole and should Pole Attachments - Forms and Specifications Drawing 1 - Communication Cable Clearances and Requirements Tangent Construction Drawing 2 - Communication Cable Clearances and Requirements Midspan 2 12. 0 TO 16. Mailing Address. The rest of your list should be covered by the utilities specification, and/or requirements of the builder. 9 meters to 7. Electric Metering Specifications and Other Guides Meter Sockets Specifications; Current Transformers; Meter Hubs; Customer-Provided Hardware Pole Attachments - Forms and Specifications Drawing 1 - Communication Cable Clearances and Requirements Tangent Construction Drawing 2 - Communication Cable Clearances and Requirements Midspan Basically, you build the pole to the utilities specifications, and follow NEC while you do it. ground rods 6 ft. f. ( Page 8, Tabular matter of fIg. ( P(Ige 8, cia11sc A-1. ) treated pole 2 As Req’d #2 stranded copper cable with 90 C Insulation rating Type RHH, THHN, THHW, or XHHW. Using generators during a "major" outage can be very dangerous to both the occupants of the home and the linemen working on the lines if not hooked up correctly (see the GENERATOR-Double Throw Safety Switch Permanent Meter Pole Specifications * A3A (PDF) 75 - 750 KVA Transformer Pad Detail * Simple Sketch (PDF) Simple Residential Sketch Example * = For Maui County, please confirm with our engineering department on actual final design details. Residential & Commercial 320-Amp Meter Loop Specifications . Length of Sections Middle. Phone Guide. The mix should contain at least 380 Kg. Move service. 5-1 Shaft: 5-1-a 7,10 meter height galvanized steel shaft octagonal cross section and tapered from bottom to top, and made of one piece. eng91-09. the customer will provide install and maintain all other meter pole - meter loop specifications 5-2019 weatherhead metal threaded conduit 1. It shall be the member’s responsibility to secure the pole in a Central Electric Cooperative P. ” 13. TOP). meter socket (ringless prefered) 1. Non-standard routing has an additional charge of $5 per foot. "Meter Enclosure" - a wood or metal cabinet, or metal socket, installed indoors or outdoors, in which the Company's metering equipment is located. of cement per cubic meter of concrete. Who owns the Meter Loop? The member owns the meter loop and is responsible for upkeep and main- Sam Houston Electric/Mid-South Utilities 200 Amp Meter Loop On 23' Pole. In addition, you can also learn about our transmission facility connection requirements, which provide information on co-generation facilities and increased voltage requests, as well as our approved meter sockets lists for both residential and commercial construction. threaded hub on top. Elliott Electric Supply. Divided across three days, each MSR got a chance to sit in on the half-day workshop. 5’ 6” 2’ 3’ max. 75 mm POLE SHAFT THICKNESS: 3 mm 3 mm ( 6. The conduit shall be installed a minimum of 24” below finished grade in as straight a line as possible from the meter location to the designated pole, pedestal or transformer. 7. We also offer delivery and connection services. MEMBER METER POLE . 200amp poles come standard on 18 ft treated pine poles. Self-Contained Meter Socket Connections (Single Phase and Network) Figure M. Self-Contained Metering 39 810. rigid or imc. Sitzler 921 County Farm Rd. (see note 7)Meter socket installed and maintainedby customer. See Figure 26. 1 UG Service - Pole Mounted Transformer (M8-10 Assembly) (Figure 5): To provide Underground Service to a permanent building from a WCEC overhead line, the existing WCEC pole or an additional 30 foot lift-pole equipped with a weatherhead, conduit, and meter base (commonly referred to as an “M8-10” pole assembly) will be provided and Meter Loop Installation Guide Deep East Texas Electric Cooperative U. 23. i. 62 (Each) Availability: Call for Availability Buy Now. Poles; Line side connectors; C&L 3 Phases Transformer Concrete Pads September 13, 2023 (PDF) C&L Underground Service August 17, 2023 (PDF) 6 7 permanent overhead service - meter pole single phase — 120/240v - 200 amp or less 6” 15’ 6” min. conduit straps 1. conduit straps . _F024. NESC Table 232-16" min. Primary Underground Installation Diagram; Underground Meter Loop Service Diagram; Meter Loop on a Free-Standing Structure Temporary Meter Loop Specifications and Descriptions. Load center includes only 200-amp service disconnect, additional breakers are extra. 5 – Meter Room Specification - (Page 47). 600 amp Double-Disconnect CT Meter - Free Standing. Residential/small non-residential 120volt (two wire) Overhead self contained; Underground self contained; 277/480 Volt service on pole (overhead) 277/480 Volt service (from a) Poles: Meter pole is to be a new southern yellow pine pole or equivalent in<br /> accordance with ANSI Spec. Overhead service to mobile home. 32 841. conductor tails . Pole with 480V/30 Amp Disconnect Spec Sheets Attached are Construction Specification Sheets showing the correct way to hook up your temporary or permanent service. Metering Multi-Tenant Buildings 36 802 Meter Location 36 803. Temporary meter loops should be installed on a minimum of a 4”X4” piece of treated lumber and must not be installed on one of the Cooperative’s primary distribution poles. 975 N Perkins Ferry Road Lake Charles, LA 70611 wood pole 12' min. Before purchasing a meter pack, please contact your Oncor Representative for approval. CALL FOR PRICE . This includes setup Features: Meter Sockets: 5, 6, 8, 13 and 15 terminal sockets available. 361-364-2220, option 2 200 Amp Complete Meter Loop on 20' Treated Pole. 2 College Station Utilities - Construction Specifications, Electric Service, & Meter Installation Guidelines 02/10/2022 What is a Meter Loop? A meter loop is the assembly that serves as the path for electrical conduc-tors to securely attach to the house or pole and the electrical meter. 410 East Houston Street Marshall, TX 75670. It will have a base diameter of 350mm, top Standard Meter Pole Specifications Mobile Home or Temporary Service (PDF) Padmount Transformer Specifications (PDF) Stay Connected. Add Half Meter Box, 100NB Pipe 100NB / 114. 0 TO 9. 5 %µµµµ 1 0 obj >>> endobj 2 0 obj > endobj 3 0 obj >/Font >/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 595. SERVICE DROP: The overhead service conductors from the last pole or other aerial support to and including the splices, if any, connecting to the service-entrance conductors at the building Applicable to residential and small noncommercial services receiving single-phase power at 120/240 volts through a 200 Amp meter base attached to a meter pole. Physical location of pole and any additional guying or bracing will be approved by the Company. O ’Brien • On SRP poles or other SRP facilities. Look for a similar product To find similar products, please select the desired Prior to scheduling of your meter installation, an approved Inspection Certification must be sent to Xcel Energy at BCLCO@xcelenergy. UG Pedestal Construction The specifications for underground pedestal construction. Self-Contained Meter Socket Connections (Single Phase and Network) Figure 24. DIA. Meter Loop for Pole Attachment Policy. 22. 6 – Meter Identification – (Page 47) Added: “All METER MOUNTING DEVICES and SERVICE Figure 21A. Figure 2 is the most commonly used underground construction practice. are required. Directions to Office. 0mm 7,Single arm at 5m height 8,Baseplate:400*400*16mm NINGBO YINGPU PHOTOELECTRICITY CO. (See section 3. 2 METER METAL POLE. Full Delivery and Installation. Please call us at (850) 892-2111 if you have any questions about new construction and setting up a new service. Self-Contained Meter Socket Connections (Three Wire and Four Wire Delta overhead serv ce, self-conta ned meter(s) on customer-owned meter pole normally nstalled by cps energy at customer's expense diameter at top of pole shall not be less than 5 nches (refer to sect on 1400. Residential Meter Pole Specs Specifications for meter sockets of more than four positions and meter pedestal assemblies shall be submitted to the Company for review and concurrence prior to meter board with multiple positions shall be mounted on a single pole. 0 MTR. Conductor s extend 36” minimum outside of weatherhead. Box 616 Corsicana, TX 75151-0616 Office: 903-874-7411 or 1-800-771-9095 For local customers in need of meter poles manufactured to Puget Sound Energy specifications, call The Oeser Company, we’ve got you covered! Puget Sound Energy (PSE) Meter Pole Specifications. Texas And New Mexico 100 Amp Meter Loop On 20'Pole. must be at least 3 ft long. RIGID, EMT, OR INTERMEDIATE MAY BE REQUIRED FOR . Specifications for Residential Overhead Meter Pole Requirements; Single-Phase Overhead Meter Pole Requirements – Drawing No. Service entrance conductor ’s FortisBC Service and Metering Guide Revision Date: September, 2023 Revision No. Schedule 40 or greater, electrical grade PVC, and the service riser to the meter socket shall include an expansion cou-pling that allows for 8” fall. Meter Socket Layout for Adding a Separately Metered Electric Vehicle Service Figure 23. 9u address shall be a minimum 3' uttering marked on meter can, pole, dr durable black material attached to pole and should be visible from street. O. Main breaker must be within 8 circuit feet of the meter. OVH Temp Service Specifications The specifications for an overhead temporary pole. Main disconnect location must meet Section 1: Foreword, General Information, and Terms 1. New Article 416. Circuit Breaker – A device designed to open and close a circuit by non-automatic means and to open the circuit automatically on a The temporary pole on which the meter loop and rain-tight enclosure are mounted shall conform to the above drawing. Date: 11/17/2010 Explore. If the receptacles are exposed to weather, then you'll need in-use covers. B09/08/2023 MMG REDRAWN, 200A Overhead Meter Pole, Tyler, TX Area. Primary OVERHEAD TEMPORARY POLE Overhead temporary meter poles shall be installed within fifty (50) feet of the Cooperative’s transformer pole and must be properly braced. Pole with Meter Base and 240V/200 Amp Disconnect. The meter This booklet provides guidelines for obtaining and installing electric service from HEC, including meter types, locations, clearances, and standards. Main Office. It is also suitable to mount camera or traffic light for outdoor use. O. meter socket 1. It is also necessary for a member to provide a meter loop that meets C&L Electric Meter on Pole specifications. The Company shall be consulted in every case before work is started so that it may designate the pole from which the service will be taken, the location of the riser on the pole and meter location. 92] /Contents 4 0 R/Group Microsoft Word - Transformer Pole Meter Loop Specifications Author: brandonp Created Date: 3/13/2023 9:59:51 AM 2 1. They are resistant to weather conditions and provide better stability. Meter Pedestals 37 806. eng83-12 contd. long. Industry Solutions Overview. 01. pdf), Text File (. RES 120V/240V, 1PH, 3W, 400A Transformer Rated Service Upgrade Using Combination Meter Socket Base – Meter Enclosure. 7; Residential Transformer Foundation Details. 0 Meter Compartment The meter pole shall be 3” thick by 12” wide of pressure treated lumber or equal self-supporting structure. 3 1 1 1/4” Weatherhead 4 4 1 1/4” conduit straps with screws (Nails NOT acceptable). Self-Contained Meter Socket Connections (Three Wire and Four Wire Delta Trinetics pole-mount primary metering provides the customer with the flexibility and cost savings of a completely factory-assembled primary metering rack with the customer’s choice of voltage and current transformers pre-wired and ready to install. ID Specification Title Rev; DFS0002: Electrical Distribution As-Built Construction Drawings : 4: ≤200A Service Entrance Disconnect and Metering on Customer Owned Pole – Construction Detail. 3OD x Meter Mounted on Pole Meter Mounted on Pole. 0 Available at San Marcos. Uses Type BR circuit breakers. The foundation details include METERING & SES Description Page Electric Service Specifications PROPRIETARY MATERIAL REV: CONTENT MOVED TO DGIH SECTION 2 -8 METERING & SES ISSUE DATE: 11/16/12 REV. protection. ) meter pole 6" to 12" refer to f cure 500. All meter bases must be wired according to certain specifications in order for Dixie Electric Cooperative to provide electric service to a home. Pole must provide sufficient height for the service drop to meet minimum clearances per NESC code. Length of Sections Bottom. E Metering Equipment – Identification of Meters Request to mark the inside of meter enclosures with address served when possible to do so Oct 2014 Fig IV-13a Service Provisions – Service to Mobile Home Added table of acceptable pole classes Oct 2014 VII Approved Meter Enclosures Updated the approved enclosure list Jan 2015 Meter Loop on Meter Pole; Meter Loop on Building Thru Roof; Meter Loop on Building Not Thru Roof Underground Meter Loop Specifications and Descriptions. 0 Residential Specifications 30 OH Service Clearances 30 Residential Underground Service Installation 31 3-Wire, OH Service, (120/240V), (225A or Less) 32 OH Service, Customer Owned Pole, Ungrounded 106 16. ” Added: “Meter Rooms shall be in readily accessible locations and meet NEC requirements. PO Box 400 New Market, TN 37820 Bill Payment Address. While Entergy is committed to providing the most reliable electrical service possible, our first priority is safety. CONDUIT PROPER CLEARANCE meter base at a readily accessible location (Section 230. Planting Depth. Minimum Customer Wiring Size - Residence Single Phase ** CONDUIT 100 Amp 320 Amp 200 Amp SIZE METER 1. Conduit shall be rigid galvanized steel or schedule 40 PVC and shall be securely fastened to the pole with suitable clamps. Typical Meter Pole Installation for Manufactured Home Center of Meter Base 5'-6' above ground DR-19 NOTES: 1. Can’t fault it 22 mm bore top kits loads fit so in awe of it . Meter sockets must co nform to specifications furnished by Tri-County Electric Co-op 4. locknut and fiber-bushing inside meter General Mailing Address. Specifications for Residential Underground Meter Pole Requirements . L ogin/ R egister P roducts Q uick B uy Quick Specs Catalog Number TXU0NC0R200A16FT Vendor Code MPW Manufacturer Meter Loops & Power Poles Manufacturer's Part Number TXU0NC0R200A16FT Description What is a Meter Loop? A meter loop is the assembly that serves as the path for electrical conduc-tors to securely attach to the house or pole and the electrical meter. The member shall own the meter rack and shall be solely responsible for the related construction, installation, and maintenance of all 100-200-AMP METER LOOP SPECIFICATIONS RESIDENTIAL AND COMMERCIAL. Monday through Friday 8 a. Electrification. Jefferson City, TN 37760 Specifications. Meter loop must pass inspection coop meter loop construction specifications december 2018 ganado office physical address: 8925 state highway 111 e ganado, tx 77962 phone: (361)771-4400 • meter poles must be round and a min of 30/6 with creosote or equivalent treatment • with a call in and scheduling, the price of a pole change out will be $350. $1,030. Temporary meter pole installation may be wired in conduit or service entrance cable, as desired by the Consumer. Pole to be treated and a minimum of 4" x 4"x 16 ft. 11 CRL Document No. traps. TN 37354 (423) 836-0684 Danny Davis Electrical 111 Everett Ave. 2 – Single-Phase Underground Service Requirements from an Existing Padmount Transformer eDrawing No. Sku: 18029956. eng84-02. Meter sockets may be mounted directly to a masonry wall using Figure 22 as a Material Technical Specifications Material Select a Material / All Materials Meters Transformers Cables and Conductors VCB,RMU,CRP,GIS AB SWITCH,ISOLATOR POLE,INSULATOR,LA,BOX,OIL Testing Equipment Others Conroe Meter Poles are the leading provider of residential Pre-Assembled Meter Poles in the Houston & Southeast Texas area. Just found one 2nd hand for £600 stiff light and well balanced . 1. Instrument Residential & Commercial 100-200-Amp Meter Loop Specifications . Has 4 spaces, 8 circuits. Be sound, round, reasonably straight, and made of wood. Box 329 716 Route 368 Parker, PA 16049 Member Services: 800-521-0570 Outages: 800-282-8610 Service to permanent pole location (serves mobile homes and some buildings) Overhead; Underground; Mobile home park (5 or more contingent lots, same owner) Meters. Specifications conforming to IS 2713. Sku: 18029924. panel and gfci receptacle MAG Metal pole black color epoxy paint design to mount long range reader for parking access. TREATED (5" MIN. Temporary meter pole BCEC-M4, Underground Meter Pedestal (PDF) BCEC-M5, Temporary Meter Pole (PDF) BCEC-M6, Permanent Meter Pole (PDF) BCEC-M7, Member Installed Service Pole (PDF) BCEC-M8, Underground Temporary Meter Pole (PDF) Bowie-Cass Transformer Pad (PDF) Bowie-Cass Meter Specification Notes. Description. Temporary meter pole provided and installed by Member. At Pearl River Valley Electric we believe in being prepared. REV OH-200-1 1 200 Amp OH Meter Pole 120/240 VAC Pole Furnished by Member Revised JM 10/20/21 Checked 1. The metering and service specifications outlined in this publication must also comply with all Drawing 6-2 Pole Metering for Oilfield Loads Over 200 A and Greater 300 V Phase to Phase %PDF-1. Who owns the Meter Loop? The member owns the meter loop and is responsible for upkeep and AESTHETIC STYLE: Tubular Pole Tubular Pole Tubular Pole TYPE: 4 Meter - Light Duty Pole 4 Meter - Medium Duty Pole 4 Meter - Heavy Duty Pole POLE HEIGHT: 4 METER 4 METER 4 METER POLE DIMENSION: Ø114mm x 4000 mm HEIGHT. 5. m. Identification of Meters 38 808. if pole is to be used as rv pole then rv plug(s) may 4' deep approved ground pod clamp 5/8 x 8' galvanized ground rod if meter pole is more than 50' from service pole, concrete around base of pole or guying is required owner is responsible for METER BOX POLE MOUNTED (WA) Electric Meter Box Pole Mounted Plain 490(W) x 510(H) x 255(D) Does this product not have all the specifications you are looking for? Please don't hesitate to conduct a search for other products with similar technical specifications. grade) or by installing it in ½-inch thin wall EMT conduit securely attached to the building or pole. 8; 16 SLEMCO Specifications for Residential Underground Meter Pole Requirements Items marked with are indicated on the following drawings: Drawing No. 3 – Single-Phase Underground Service Requirements from a new Padmount Transformer rDrawing No. Filename Subtract Currently in stock at over 200 retail stores, we’ve been building meter loops and meter poles for more than 20 years, with thousands now in use throughout Texas, Louisiana and Arkansas. Neutral wire must meter pole fails to meet required specifications, the 400 amp Double-Disconnect CT Meter - Free Standing. (SEE NOTE 3) NO "TIMBER" STRUCTURE ACCEPTED. Covenant Electric LLC John D. Self-Contained Meter Socket Connections (Three Wire and Four Wire Delta VI. Industry Solutions. To ensure the safety of our customers, employees, your employees, and the contractors we each employ, it is imperative that every third-party attachment to Entergy facilities comply with National Electric Safety Code standards as well as Entergy construction 4-4 Types of poles: Four types of poles are required, 7, 10, 12 and 15 meter height. com. PO Box 710. The mast will be made of steel, tapered in shape, between 4-12 sections, and hot dip galvanized. 70). preservative treated southern pine crossarms. Multiconnection Points 38 807. MAG Metal pole black color epoxy paint design to mount long range reader for parking access. Underground Stick Build Service Entrance; Underground Mobile Home Service Entrance; Underground Temporary Meter Pole; Standard underground service utilizes the shortest route possible up to 150 feet – See A below. Be sure all items shown below are on the meter pole before contacting the office for connection of electric service. 1-3 — Meter Pole (Single-phase Underground Load Connection) Installation Specifications. The meter pole height above grade should be a minimum of 6’ above finished grade and high enough such that the center of the meter base socket window can be Meter Pole Location Guide For Mobile Home Underground Service: Temporary Underground Service Pole: Back Up Generation : Transfer Switch Options For Standby Generator: Commercial Metering (For Services Above 400 Amps Single Phase Or 200 Amps Polyphase And All Services Requiring 480 Volts) Transformer Rated Service Entrance – For Overhead or Service / Meter Pole Specifications. "Meter Sockets" - a meter socket is the base portion of a socket type meter. Our products are proudly built in our modern facility using quality components from leading suppliers like Eaton/Cutler Hammer, Siemens, GE, Square D, Madison 3. METERING EQUIPMENT 35 800. Revisions to Both Specifications • Page 1 o Note 5: Added Splicing is not permitted within meter sockets. $70. Release for Electric Service (PDF) This is a 200 AMP meter loop assembly built on a 22' Treated Pole providing 12' cleareance when installed properly. Material - electrical phenolic and plated copper. Ø165mm x 6. eng97-03. We recommend you use a licensed electrician for the installation. » Contact Us. 25ft Power Pole with 200-Amp Cutler Hammer Meter Base & Load Center with 4 Space Circuits and 8 Single Pole Circuits Figure 2. 5) 8 M AND 9 M LENGTH 1. xtt nqqow hfxztfia fhff jdsyld uat npz qpfiq odnklwz pdyeyud